ELD600 flex, D13530010
Part Number: D13530010
Added to Your Shopping Cart
ELD Leak Detector
The ELD600 precision leak detector is designed for fast, accurate leak detection in a wide range of applications, fully mobile and with an easy to control interface. Featuring with low energy consumption, extended warranty and even longer life ion source, Edwards ELD600 leak detector ensures exceptional low cost of ownership with no compromise on performance. Available in three variants: ELD600, ELD600 FLEX, and ELD600 DRY, Edwards ELD600 leak detector is versatile. All models feature a rugged turbomolecular pump optimised for the rigours of portable leak detection, ideal across all applications.
Features and Benefits
- Detachable colour touchscreen control with local graphical display and audible leak detection.
- MOBILE SOLUTION - Low weight and integrated carry handles which allow it to be bench-top or trolley mounted.
- HIGH SENSITIVITY - Measurement of leaks in vacuum mode and sniffer mode.
- CUSTOMISABLE FOR ANY APPLICATION - ELD600 dry version with an integrated helium optimised scroll pump - ELD600 flex version without a primary pump
- ACCURATE PIN-POINTING OF LEAKS - Standard sniffer line enables operation up to 5m from the ELD600. Longer sniffer lines of up to 50m can be used with the QT 100 sniffer extender.
General Product Information
| Connection Inlet Flange | DN 25 ISO-KF (NW25) |
| Weight | 30.00 |
| Power Supply Phase | 1-Ph |
| Power Supply Voltage | 1Ph 200-240V AC 50Hz/60Hz |
| Dimension Length | 0.495 |
| IP Rating | IP40 |
| Power Supply Frequency |
50 Hz
60 Hz |
| Dimension Height | 0.456 |
| Dimension Width | 0.495 |
| Connector Electrical Power | IEC EN60320 C14 - Male (for C13 plug on mains cable) |
| Available Units of Measurements | mbar*l/s |
| Cooling Method | Air Cooling (forced - fan) |
| Dimension Comments | The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models. |
Performance Data
| Pumping Speed Helium in Fine Mode | 3.100 × 10⁻³ |
| Ramp Up Time | 120.00 |
| Warm Up Time | 120.00 |
| Lowest Detectable Leak Rate for Helium (Vacuum | Sniffer) | 5.000 × 10⁻¹³ |
Environmental Conditions
| Temperature Ambient Operation Max | 313.15 |
| Temperature Ambient Operation Min | 283.15 |
| Temperature Ambient Storage Min | 263.15 |
| Temperature Ambient Storage Max | 333.15 |
Operation Conditions - Limitations
| Pressure Absolute Inlet Continous Max | 1500.00 |
| Altitude Max | 2000.00 |
Classification
| Classification Principle of Measurement | Helium leak detector - sector field mass spectrometer |
| Classification High / Medium / Rough Vacuum pump | High Vacuum Pump |