Specifications

Gamma Pump Element DI - Noble diode
Gamma Port Option 18 - 2 ports DN200/160 CF (10"/8"CF) inline
Gamma Pump/Controller Connector SC - 10kV SAFECONN
Gamma Heater Voltage 2 - 240 V
Gamma TSP NEG Option TC - TSP and Cryoshrout

1200LX TITAN ION PUMP

Part Number: 1200LXDI18SC2TC

Variant

Explore the range of variants given below to compare the product

Short Description Part Number Gamma Pump Element Gamma Port Option Gamma Pump/Controller Connector Gamma Heater Voltage Gamma TSP NEG Option
1200LXCV10SC2N CV - Conventional diode 10 - Single DN200CF (10"CF) SC - 10kV SAFECONN 2 - 240 V N - None
1200LXCV10SCNN CV - Conventional diode 10 - Single DN200CF (10"CF) SC - 10kV SAFECONN N - No Heater N - None
1200LXCV18SC2TA CV - Conventional diode 18 - 2 ports DN200/160 CF (10"/8"CF) inline SC - 10kV SAFECONN 2 - 240 V TA - TSP and Ambient Shield
1200LXCV18SC2TC CV - Conventional diode 18 - 2 ports DN200/160 CF (10"/8"CF) inline SC - 10kV SAFECONN 2 - 240 V TC - TSP and Cryoshrout
1200LXCV8DSC1N CV - Conventional diode 8D - 2 ports inline DN160CF (8"CF) inline SC - 10kV SAFECONN 1 - 110 V N - None
1200LXCV8DSC1TC CV - Conventional diode 8D - 2 ports inline DN160CF (8"CF) inline SC - 10kV SAFECONN 1 - 110 V TC - TSP and Cryoshrout
1200LXCV8DSC2N CV - Conventional diode 8D - 2 ports inline DN160CF (8"CF) inline SC - 10kV SAFECONN 2 - 240 V N - None
1200LXCV8DSC2TC CV - Conventional diode 8D - 2 ports inline DN160CF (8"CF) inline SC - 10kV SAFECONN 2 - 240 V TC - TSP and Cryoshrout
1200LXCV8DSCNTC CV - Conventional diode 8D - 2 ports inline DN160CF (8"CF) inline SC - 10kV SAFECONN N - No Heater TC - TSP and Cryoshrout
1200LXCV8SSC2N CV - Conventional diode 8S - Single DN160CF (8"CF) SC - 10kV SAFECONN 2 - 240 V N - None
1200LXCV8SSCNN CV - Conventional diode 8S - Single DN160CF (8"CF) SC - 10kV SAFECONN N - No Heater N - None
1200LXCX18SC1NG CX - Conventional diode XHV optimized 18 - 2 ports DN200/160 CF (10"/8"CF) inline SC - 10kV SAFECONN 1 - 110 V NG - 400NP - 400 l/s pressed NEG (>100L)
1200LXDI10OV2N DI - Noble diode 10 - Single DN200CF (10"CF) OV - Old Varian 2 - 240 V N - None
1200LXDI10SC2N DI - Noble diode 10 - Single DN200CF (10"CF) SC - 10kV SAFECONN 2 - 240 V N - None
1200LXDI10SCNN DI - Noble diode 10 - Single DN200CF (10"CF) SC - 10kV SAFECONN N - No Heater N - None
1200LXDI18SC1N DI - Noble diode 18 - 2 ports DN200/160 CF (10"/8"CF) inline SC - 10kV SAFECONN 1 - 110 V N - None
1200LXDI18SC2TA DI - Noble diode 18 - 2 ports DN200/160 CF (10"/8"CF) inline SC - 10kV SAFECONN 2 - 240 V TA - TSP and Ambient Shield
1200LXDI18SC2TC DI - Noble diode 18 - 2 ports DN200/160 CF (10"/8"CF) inline SC - 10kV SAFECONN 2 - 240 V TC - TSP and Cryoshrout
1200LXDI18SCNTA DI - Noble diode 18 - 2 ports DN200/160 CF (10"/8"CF) inline SC - 10kV SAFECONN N - No Heater TA - TSP and Ambient Shield
1200LXDI8DSC2TA DI - Noble diode 8D - 2 ports inline DN160CF (8"CF) inline SC - 10kV SAFECONN 2 - 240 V TA - TSP and Ambient Shield
1200LXTR18SCNNG TR - Triode 18 - 2 ports DN200/160 CF (10"/8"CF) inline SC - 10kV SAFECONN N - No Heater NG - 400NP - 400 l/s pressed NEG (>100L)
1200LXTR8DSCNNG TR - Triode 8D - 2 ports inline DN160CF (8"CF) inline SC - 10kV SAFECONN N - No Heater NG - 400NP - 400 l/s pressed NEG (>100L)

Classification

Classification High / Medium / Rough Vacuum pump High Vacuum Pump
Classification Dry or Wet Pump Dry
Classification Product Pressure Range Ultra High Vacuum: 1·10⁻⁷ - 1·10⁻¹¹ mbar
Extreme Ultra High Vacuum XHV: < 1·10⁻¹¹ mbar
Classification Vacuum Pump Technology Ion Getter Pump

Performance Data

Pumping Speed Air Nitrogen 1.20
Pressure Ultimate 1.000 × 10⁻⁹

Operation Conditions - Limitations

Temperature Baking Max 250.00
Temperature Baking Max (Magnets Removed) 450.00

Variants

Gamma Pump Element DI - Noble diode
Gamma Pump/Controller Connector SC - 10kV SAFECONN
Gamma Pump Type 1200LX
Gamma Heater Voltage 2 - 240 V
Gamma Port Option 18 - 2 ports DN200/160 CF (10"/8"CF) inline
Gamma TSP NEG Option TC - TSP and Cryoshrout